Operating
Diagnostics
Use the CLI, admin API, and process logs to inspect a running proxy or investigate a failed startup.
On this page
Use the CLI, admin API, and process logs to inspect a running proxy or investigate a failed startup.
Version and Configuration
Run these commands with the same binary, configuration, and environment as the affected instance:
praxis --version
praxis --validate --config praxis.yaml
praxis --dump --config praxis.yaml > effective-config.yaml
--validate and --dump exit without binding listeners.
Both return a non-zero exit status on failure and write
warnings and errors to stderr. Listener startup can still
fail if a port is unavailable or TLS files cannot be loaded.
The dump includes configuration defaults and resolved top-level listener chains. It reads the file on disk; after a failed reload, the running proxy may still use an older config. Known secrets are redacted by name, but custom secret fields may remain. Review the output before sharing it.
See Validating Configuration and Dumping Effective Configuration for details.
Live State
The examples below use separate admin and health/metrics listeners:
admin:
address: "127.0.0.1:9901"
metrics_address: "127.0.0.1:9902"
Both require the admin-api build feature, enabled by
default. Neither listener has authentication. Keep the
admin interface on loopback or a trusted, access-controlled
network, and restrict access to health and metrics too.
See Admin for binding restrictions.
Inspect the running proxy:
curl -fsS http://127.0.0.1:9901/api/stats
curl -fsS http://127.0.0.1:9901/api/pipelines
curl -sS -i http://127.0.0.1:9902/ready
curl -fsS http://127.0.0.1:9902/metrics
| Endpoint | What to check |
|---|---|
GET /api/stats | version.display, uptime, listener activity and upstream health. version.git_sha is present when available at build time. |
GET /api/pipelines | Resolved live pipelines, including branches. Use ?listener=NAME to inspect one listener. |
GET /healthy | Liveness: 200 once the listener accepts requests. |
GET /ready | Upstream readiness: 503 when a cluster has no healthy endpoints. With no health checks, this returns 200. |
GET /metrics | Request, error, health and reload metrics. |
/api/* uses port 9901 in this example; health and metrics
use 9902. /ready is an upstream health check, not a
drain-status endpoint. Enable admin.verbose only when
per-cluster readiness detail is needed; it exposes
internal topology.
See Observability for endpoint responses and metric definitions, and Health Checking for probe behaviour.
Temporary Debug Logging
Read the current log settings, then enable debug logging for the config watcher for five minutes:
curl -fsS http://127.0.0.1:9901/api/log-level
curl -fsS -X PUT http://127.0.0.1:9901/api/log-level \
-H 'Content-Type: application/json' \
-d '{"module":"praxis::watcher","level":"debug","duration_secs":300}'
The overlay expires automatically. Clear it early with:
curl -fsS -X DELETE 'http://127.0.0.1:9901/api/log-level?module=praxis::watcher'
See Runtime Log Levels for global overlays and limits.
For startup failures, use RUST_LOG and
PRAXIS_LOG_FORMAT=json when starting the process; the
admin API is only available after startup.
Startup and Reload Failures
Keep the startup or reload error and the preceding log
messages. Warnings identify active insecure_options,
experimental features and unsafe file permissions.
With the default Pingora backend, an occupied listener address causes binding to retry before failing. The admin endpoints may still respond; test the affected listener too.
For reloads, look for config reload complete or
config reload failed and the accompanying error.
Rejected configurations leave the previous pipelines
serving traffic. A requires restart warning means a
startup-only setting has not taken effect.
The metrics praxis_config_reload_total{result="success"}
and praxis_config_reload_total{result="failure"} count
reload outcomes. praxis_config_reload_last_success_timestamp
records the last successful reload as Unix time in seconds.
Compare these with /api/pipelines and the process logs
when checking whether an edit took effect.
See Dynamic Configuration Reload for settings that can reload and changes that require a restart or are rejected.
Draining Before Shutdown
Stop routing new traffic to the instance before sending
SIGTERM. Wait for active work to finish, using
praxis_http_active_requests for HTTP and
praxis_tcp_active_connections for TCP, together with
the access logs. Long-lived streams may need a separate
drain window.
With the default Pingora backend, the request grace period
after SIGTERM is at most five seconds. Increasing
shutdown_timeout_secs does not extend that period.
Long-lived and streaming responses can therefore be
interrupted when the grace period expires; drain them before
SIGTERM when they need more time.
Allow time for shutdown and for logs and spans to flush
before forcing the process to exit.
See Graceful Shutdown for the timeout behaviour.